Download presentation
Presentation is loading. Please wait.
1
The IBM Virtualization Engine™ TS7700
Automate and simplify IT operations
2
Agenda Introduction Virtual Tape Concepts Product Overview
Virtualize Everything Commit to Openness Collaborate to Innovate Agenda Introduction Virtual Tape Concepts Product Overview Subsystem Performance Potential Business Benefits Product Roadmap Technology VTS Migration
3
Introduction
4
테이프의 History 1952년 시작 2007년 현재 IBM 726 테이프 유닛 IBM TS1040 테이프 드라이브
초당 7,500 문자 인치당 100 비트 2007년 현재 IBM TS1040 테이프 드라이브 최대 120 MB/sec1 최대 800 GB1 2000 LTO Gen1 2002 LTO Gen2 2004 LTO Gen3 2007 LTO Gen4 1848 George Boole invents binary algebra 1952 IBM 726 1st magnetic tape drive 1964 IBM 2104 1st read/back drive 1995 IBM 3590 O P E N E N T E R P R I S E 1928, IBM invents the 80 column Punch Card 1959 IBM 729 1st read/write drive 1984 IBM 3480 1st cartridge drive 1999 IBM 3590E 2003 3592 Gen1 2005 3592 Gen2 1 represents maximum native performance or cartridge capacity
5
Source: Disk - Industry Analysts, Tape - IBM
테이프 역할의 진화 Tape는 스토리지 계층 구조의 필수 요소입니다. 고객은 디스크의 4~15배 이상 데이터를 테이프에 저장합니다. Tape는 비용이 낮습니다. Tape의 본질은 “온 디맨드”입니다. Tape는 이동식으로 휴대가 가능합니다. Tape는 대용량의 효율성을 제공합니다. Tape 미디어는 수명이 깁니다. Tape는 다음에 적합합니다: 정보 수명 주기 관리 인프라 단순화 비즈니스 연속성 Source: Disk - Industry Analysts, Tape - IBM
6
Virtual Tape Concepts
7
제품 개발 목적 스토리지 계층 구조를 활용할 수 있는 서브 시스템 개발 데이타는 테이프에 저장된다는 사실은 기본적으로 전제
장애 발생시 비지니스 연속성 지원 필요 장기 보관 또는 관련 규제 법률 지원 필요 데이타 특성에 따른 다양한 접근 요구에 부합 신속한 접근 필요 데이타는 디스크에 위치한 ‘가상 볼륨’에 저장 ‘가상 볼륨’을 테이프로 이전 시킴으로써 비용 효율적인 스토리지 제공
8
가상 테이프 개념 가상 테이프 드라이브 테이프 볼륨 캐싱 볼륨 스태킹 ( Volume Stacking )
180 181 19F . . . 가상 테이프 드라이브 복수개의 3490E 테이프 드라이브로 보임 물리적인 테이프 드라이브와 동일하게 공유/파티션 됨 좀더 적은 수의 테이프 드라이브 필요 테이프 볼륨 캐싱 물리적 테이프의 지연을 제거하기 위하여 고안 데이타 읽기시 cache hit 또는 카트리지에서 검색 지원 데이타 쓰기시 100% cache hit 지원 볼륨 스태킹 ( Volume Stacking ) 카트리지와 라이브러리 용량을 최대한 활용하기 위해 고안 복수개의 가상 볼륨을 다수의 카트리지에 저장 TS1120 및/혹은 3592 J1A 테이프 드라이브 지원 Virtual Drive 1 Virtual Drive 2 Virtual Drive n Tape Volume Cache Virtual Volume 1 Virtual Volume 2 Virtual Volume n It is assumed that the speaker understands concept, characteristics and functionality of a VTS. Logical Volume 1 TS1120 up to 2.1TB capacity1 Logical Volume n 1assumes 3:1 compression
9
TS7700 가상화 엔진 운영 가상 볼륨 복제 기능 부가적인 캐쉬 공간 관리 물리적인 카트리지 용량 자동 관리 목적:
180 181 19F . . . 가상 볼륨 복제 기능 목적: cache hit을 최대화 가상 볼륨으로 캐쉬를 최대로 유지 필요시 여유 공간 제공 (사전)복제 절차를 통해 구현 논리적 볼륨은 FIFO 순서로 복제됨 End of Volume (EOV)가 완료된 후 스케쥴화 호스트로부터 비동기 방식으로 복제 수행 부가적인 캐쉬 공간 관리 SMS preference groups PG0/PG1 Last Recently Used (LRU) algorithm 사용 물리적인 카트리지 용량 자동 관리 논리적 볼륨 만료로 발생한 “gap” 재사용 사용자가 정책을 설정하여 카트리지 재사용 여부 관리 가능 Virtual Drive 1 Virtual Drive 2 Virtual Drive n Tape Volume Cache Virtual Volume 1 Virtual Volume 2 Virtual Volume n Logical Volume 1 TS1120 up to 2.1TB capacity1 Logical Volume n 1 assumes 3:1 compression
10
Peak Performance is a key measurement criteria
TS7700 가상화 엔진 성능 Physical Device Time to Process 14MB/s 180 ~3MB/s Job1 Job4 Job6 14MB/s 181 ~3MB/s Job2 Job3 Job5 Job7 Job n Virtual Device 150 ~3MB/s Job1 151 ~3MB/s Job2 Total TS7700 Bandwidth 152 ~3MB/s Job3 153 ~3MB/s Job4 max. n ~3MB/s Job n Peak Performance is a key measurement criteria
11
Product Overview
12
TS7700 가상화 엔진 개요 획기적인 아키텍쳐 개선 포함 더 향상된 성능과 용량 제공
향후 향상 기능을 활용하기 위한 아키텍쳐 재설개 성능과 용량을 향상시키기 위한 IBM 기술 개선 비지니스 연속성 요구 환경을 위해 유연성 향상과 비용 절감을 제공하는 새로운 옵션 제공 더 향상된 성능과 용량 제공 최대 560MBps까지 성능 지원 최대 18TB까지 native cache capacity (3:1 compression) 지원 IBM TS1120 및/혹은 3592 J1A 테이프 드라이브 연결 지원 더 신속한 cache miss recall time과 migration datarate 지원 3592 JB cartridge에서는 최대 700GB 용량 지원 TS3500 혹은 3494 테이프 라이브러리 내의 테이프 드라이브 지원 TS1120 데이타 암호화 지원 비지니스 연속성을 위한 부가적인 GRID 기능 제공
13
소프트웨어 아키텍쳐 재설개 B10 / B20 Architecture (Monolithic) TS7700 Architecture
(Modular) Virtualize Channel Interface Virtualize Tape Controller Virtualize Tape Drives Virtual Volumes Provide Management GUI Manage Logical and Physical Volumes Manage Tape Library and Tape Drives Manage Tape Volume Cache Space Manage Cartridge Media Space Volume Replication Overlay
14
TS7700 가상 엔진 요소 테이프 프레임1 36u 마운팅 공간 제공 프레임 고가용성 지원 단일 TS7740 가상화 엔진
이중 전원 공급 장치 Two power feeds 1 Machine Type 3952 Model F05
15
TS7700 가상화 엔진 요소 TS7740 노드1 고 성능 IBM System p 서버 캐쉬 증설 (FC5267)
2개 dual-core, 64-bit, 1.9-GHz 프로세서 2~4개 4Gbps FICON 호스트 인터페이스 2개 1Gbps 복제 링크 추가 아답터 물리적 라이브러리와 드라이브 연결 (fiber) 관리 인터페이스 (이더넷) 서비스 인터페이스 (이더넷) 캐쉬 증설 (FC5267) 1 ~ 6 1TB 증가 가능 성능 증설 (FC5268) 최대 6개, 100MBps 증가 캐쉬 갯수와 performance increment feature가 동일할 필요는 없음 고 가용성 지원 이중 전원 핫 스왑 전원 및 팬 1 Machine Type Model V06
16
TS7700 가상화 엔진 요소 TS7740 캐쉬 컨트롤러1 고성능 RAID 5 디스크 테이프 볼륨 캐쉬 고가용성 지원
Usable 용량 기준 최대 1.5TB 지원 16개 15k rpm 146GB FC HDD 포함 4개 4Gbps FC 인터페이스 포함 고가용성 지원 이중 전원 자동 HDD hot sparing과 rebuild 이중 핫 스왑 요소 Raid Controller 전원 공급장치 Enclosure 팬 하드 디스크 1 Machine Type 3956 Model CC6
17
TS7700 가상화 엔진 요소 최대 3개 TS7740 Cache Drawer1 Each TS7740 cache drawer
고 성능 RAID 5 디스크 어레이 지원 1, 2, 4개 드로워 캐쉬 구성 2개 drawer시 최대 3TB 용량 – 캐쉬 컨트롤러와 1개 cache drawer 4개 drawer시 최대 6TB 용량 – 캐쉬 컨트롤러와 3개 cache drawer 1TB 캐쉬 구성시 cache drawer는 불필요 1TB 캐쉬 구성은 추가 drawer를 증설할 수 없음. Each TS7740 cache drawer 고성능 RAID 5 디스크 TS7740 cache controller에 연결 Usable 기준 최대 1.5TB 캐쉬 용량 지원 Includes 16 15k rpm 146GB FC HDDs 고가용성 지원 이중 전원 자동 hot sparing/rebuild 이중 핫 스왑 요소 전원 공급장치 Enclosure 팬 하드 디스크 1 Machine Type 3956 Model CX6
18
TS7700 Two Cluster GRID 구성 GRID 구성을 위하여 두개의 TS7700 클러스터를 연결
I/P Links GRID Configuration TS7700 GRID 구성을 위하여 두개의 TS7700 클러스터를 연결 VTC는 제거됨 호스트가 TS7700 클러스터에 직접 연결 GRID 구성내 두 TS7700 클러스터를 통해 임의의 볼륨에 접근 가능 I/P 기반 복제 두개의 1Gbps 이더넷 링크 RJ45 Copper (Cat 6) FC1030 Optical Fiber FC 1031 표준 TCP/IP 정책 기반의 복제 관리 재해 복구 또는 고 가용성 환경에서 구성 가능 Hosts TS1120/TS3500 Optional connections Optional Hosts TS1120/TS3500 As a business continuation solution, two TS7700 Clusters can be interconnected using standard 1Gb ethernet connections. Local as well as geographically separated connections are supported to provide a great amount of flexibility to address customer needs. The Virtual Tape Controllers and remote channel extension hardware of the prior generation’s PTP VTS have been eliminated, providing the potential for significant simplification in the infrastructure needed for a business continuation solution as well as simplified management. Hosts attach directly to the TS7700s and instead of FICON or ESCON, the connections between the TS7700 Clusters uses standard TCP/IP fabric and protocols. The TS7740 Virtualization Engine provides two independent 1GBps Ethernet ports for interconnection. The Ethernet ports use copper and it is highly recommended that Cat 6 cabling be used to utilize the bandwidth capability of the 1 Gbps interfaces. Like the prior generation’s PTP VTS, with the new TS7700 Grid configuration, data may be replicated between the clusters based on customer established policies. Any data can be accessed through either of the TS7700 Clusters regardless of which system the data resides on, as long as it has a copy. Please turn to the next slide. I/P 복제는 IBM의 기존 PTP VTS과 같은 재해 복구 솔루션과 비교하여 인프라 스트럭쳐 및 관리를 혁신적으로 단순화할 수 있음
19
고 가용성을 위한 TS7700 Two Cluster GRID 구성
LAN을 통해 상호 연결 호스트는 양 TS7700에 연결 데이타는 두 TS7700를 통해 접근 가능 한 TS7700 장애시 Ownership Takeover Manager가 자동적으로 수행됨 Hosts TS1120/TS3500 I/P Links LAN TS1120/TS3500 The TS7700 Grid configuration may be configured for a high availability environment, a disaster recovery environment or both. This slide shows a typical configuration for a high availability environment. Both of the TS7700s in the Grid configuration are located at the same site. They are connected through a Local Area Network. Production workloads are written using the virtual tape device addresses in both of the TS7700s. Data written to one TS7700 is replicated to the other. In the event of a failure or the need to service one of the TS7700s, customer applications may continue to access all logical volumes through the remaining operational TS7700, assuming it has a valid copy. In order to access the logical volumes owned by the unavailable TS7700, the operational TS7700 is enable for ownership takeover. This allows it to access and modify any volumes that were owned by the unavailable TS7700. Ownership takeover mode is very similar to the PTP VTS’s Read/Write Disconnected mode which allowed a PTP to provide access to data in the event the master VTS became unavailable. Please turn to the next slide. Ownership takeover는 PTP VTS의 Read/Write Disconnected 모드와 유사
20
재해 복구를 위한 TS7700 Two Cluster GRID 구성
WAN을 통해 상호 연결 disaster recovery host만 원격 TS7700에 연결 로컬 TS7700 장애시 원격 TS7700에서만 데이타 접근 가능 한 TS7700 장애시 Ownership Takeover Manager가 자동적으로 수행됨 Production Site Hosts TS1120/TS3500 I/P Links WAN This slide shows a typical configuration for a disaster recovery environment. One of the TS7700s in the Grid configuration is located at the production site and one is located at the disaster recovery site. The TS7700s are connected through a Wide Area Network. Production workloads are written using the virtual tape device addresses in the TS7700 located at the production site and replicated to the TS7700 at the disaster recovery site. In the event of a disaster that left the production site unusable, customer operations may resume at the disaster recovery site by running production applications on the disaster recovery host. Prior to starting the production runs on the disaster recovery host, the TS7700 at the disaster recovery site is enabled for ownership takeover. This allows it to access and modify any volumes that were owned by the production site when it became unusable. Note that there are no connections between the production host and the TS7700 at the disaster recovery site. If it is necessary to service the TS7700 at the production site or if it has failed, there will be no access to the data from the production site during service. Please turn to the next slide. Disaster Recovery Hosts TS1120/TS3500 Disaster Recovery Site Ownership takeover는 PTP VTS의 Read/Write Disconnected 모드와 유사
21
재해 복구 및 가용성을 위한 TS7700 Two Cluster GRID 구성
WAN을 통해 상호 연결 로컬 호스트는 확장 FICON 인터페이스를 통해 원격 TS7700에 연결함으로써 양 TS7700을 통해 데이타 접근 가능 필요한 경우 디바이스를 온라인 시킴 한 TS7700 장애시 Ownership Takeover Manager가 자동적으로 수행됨 Production Site Hosts TS1120/TS3500 I/P Links FICON Channel Extension WAN This slide shows a typical configuration for both a disaster recovery environment and a high availability environment. As in the prior slide, one of the TS7700s in the Grid configuration is located at the production site and one is located at the disaster recovery site. The TS7700s are connected through a Wide Area Network. Production workloads are written to the TS7700 located at the production site and replicated to the TS7700 at the disaster recovery site. In the event of a failure of the TS7700 at the production site or the need to service it, access to the replicated data at the disaster recovery site is required. This is provided by extending FICON channels between the production hosts and the TS7700 located at the disaster recovery site. When needed, the virtual device addresses in the TS7700 at the disaster recovery site are varied online to the production hosts after ownership takeover has been enabled. All data that has been copied is now accessible. It is recommended that the virtual device addresses in the TS7700 at the disaster recovery site are varied online to the production hosts only when needed, otherwise customers may experience job runtime differences because of differences in local and remote channel attached performance. Please now turn to the next slide. Disaster Recovery Hosts TS1120/TS3500 Disaster Recovery Site Ownership takeover는 PTP VTS의 Read/Write Disconnected 모드와 유사
22
재해 복구 및 가용성을 위한 TS7700 Three Cluster GRID 구성
Metro Sites 두개의 TS7700는 100km 이내 위치 LAN을 통해 상호 연결 호스트는 양 TS7700에 연결 세번째 TS7700는 원격지에 위치하며 WAN을 통해 연결 Metro 사이트간 immediate 복제 원격 사이트에서는 주로 deferred copy 적용 Immediate 본제는 중요 볼륨만을 위해 확보 가상 디바이스는 장애 복구시 또는 장애 복구 테스트시를 제외하고는 offline됨 TS1120/TS3500 Hosts LAN I/P Links WAN TS1120/TS3500 Remote Site This slide shows a typical configuration for a disaster recovery environment. One of the TS7700s in the Grid configuration is located at the production site and one is located at the disaster recovery site. The TS7700s are connected through a Wide Area Network. Production workloads are written using the virtual tape device addresses in the TS7700 located at the production site and replicated to the TS7700 at the disaster recovery site. In the event of a disaster that left the production site unusable, customer operations may resume at the disaster recovery site by running production applications on the disaster recovery host. Prior to starting the production runs on the disaster recovery host, the TS7700 at the disaster recovery site is enabled for ownership takeover. This allows it to access and modify any volumes that were owned by the production site when it became unusable. Note that there are no connections between the production host and the TS7700 at the disaster recovery site. If it is necessary to service the TS7700 at the production site or if it has failed, there will be no access to the data from the production site during service. Please turn to the next slide. TS1120/TS3500 Disaster Recovery Hosts ?
23
재해 복구를 위한 TS7700 Three Cluster GRID 구성
Data Center 두개의 TS7700는 독립적인 데이타 센타에 위치 호스트는 상호 연결되지 않음 TS7700간 상호 데이타 복제는 않음 세번째 TS7700는 DR를 위하여 우선적으로 deferred copy를 받음 TS1120/TS3500 Hosts Data Center WAN I/P Links TS1120/TS3500 DR Site This slide shows a typical configuration for a disaster recovery environment. One of the TS7700s in the Grid configuration is located at the production site and one is located at the disaster recovery site. The TS7700s are connected through a Wide Area Network. Production workloads are written using the virtual tape device addresses in the TS7700 located at the production site and replicated to the TS7700 at the disaster recovery site. In the event of a disaster that left the production site unusable, customer operations may resume at the disaster recovery site by running production applications on the disaster recovery host. Prior to starting the production runs on the disaster recovery host, the TS7700 at the disaster recovery site is enabled for ownership takeover. This allows it to access and modify any volumes that were owned by the production site when it became unusable. Note that there are no connections between the production host and the TS7700 at the disaster recovery site. If it is necessary to service the TS7700 at the production site or if it has failed, there will be no access to the data from the production site during service. Please turn to the next slide. TS1120/TS3500 Hosts Disaster Recovery Hosts ?
24
TS7700 GRID 구성 요약 마이그레이션을 단순화 하기 위하여 호스트에서는 standalone을 포함한 모든 TS7700 구성을 PTP VTS 처럼 인식 FC 4015 – GRID Enablement를 통해 활성화 VTC는 삭제됨 TS7700간 IP 인터페이스 사용 고가용성을 위해서 TS7700에 호스트 연결 필요. channel extension equipment가 필요할 수 있음 TS7700 I/P Links In summary, the TS7700 Grid configuration introduces new flexibility for designing business continuity solutions. Peering is integrated into the base architecture and design. Even for a standalone configuration, the view the host has of the TS7700 is that of a PTP VTS, with composite and distributed library IDs. This is to ease later migration from a standalone to a Grid configuration. No special hardware is required to interconnect the TS7700s, the VTCs of the prior generations PTP VTS have been eliminated and the interconnection interface changed to standard IP networking. If configured for high availability, host connectivity to the virtual device addresses in both TS7700s is required to maintain access to data in the case of a failure of one of the TS7700s. If they are located at different sites, channel extension equipment will be required to extend the host connections. The TS7700 Grid architecture has been designed to allow expansion of the solution to include a three site solution as stated in a prior statement of direction. Please turn to the next slide. GRID Configuration
25
TS7700 Virtualization Engine 상세
Specification TS7740 Model B10 Model B20 Model B18 가상 디바이스 갯수 256 64 128 Usable 캐쉬 용량 1 to 6TB enablement 216 – 432GB 864GB to 1.7TB 72GB to 1.7TB 압축시 캐쉬 용량 (3:1) 3 to 18TB enablement 648GB to 1.2TB 2.4TB to 5.2TB 216GB to 5.2TB FICON 4 2 8 ESCON Channels 16 TS1120/3592 Tape Drive 연결 4 - 16 4 - 12 3590 Tape Drive 연결 4 - 6 3 - 6 가상 볼륨 갯수 1,000,000 250,000 500,000 FICON 당 논리적 경로 업그레이드 경로 제공 Yes
26
향상된 정책 관리 고급 기능 테이프 볼륨 캐쉬 관리 Volume Pooling 선택적인 Logical Volume Copy
가상 볼륨을 캐쉬에 보관하기 위한 기준 제시 Volume Pooling 물리적인 볼륨들을 논리적인 볼륨으로 그룹화 함 선택적인 Logical Volume Copy 다른 스토리지에 논리적 볼륨 복제본을 이중화 하기 위함 Cross-site Replication 다른 사이트에 논리적 볼륨의 복제본을 생성하기 위하여 GRID 구성에서 사용 Logical Volume Sizes 더 큰 논리적 볼륨 사이즈를 선택하기 위하여 사용 (최대 4,000 MB) Secure Data Erase 삭제하기 전에 카트리지에 저장되어야 하는 기간을 제한 Copy Export standalone/GRID TS7700에서 논리적 볼륨을 익스포트 하기 위해 사용
27
Tier 3 Business Continuity 지원
TS7700 Cache 1 Primary Volume P CPU Production Site TCDB = 1, 2 TMC = 1, 2 2 Duplex Copy Global Mirror Optional FICON TCP/IP Replication S 1 Duplex Copy Recovery Site TCDB = 1, 2 TMC = 1, 2 2 Primary Volume TS7700 Cache This diagram is meant to illustrate the logical process of the primary and secondary virtual volume copy creation, and does not include all steps in the process.
28
Tier 5 Business Continuity 지원
TS7700 Cache CPU 1 Primary Volume TCDB = 1, 2 TMC = 1, 2 P Production Site 2 Duplex Copy Global Mirror Optional FICON TCP/IP Replication CPU S 1 Duplex Copy Recovery Site TCDB = 1, 2 TMC = 1, 2 2 Primary Volume TS7700 Cache This diagram is meant to illustrate the logical process of the primary and secondary virtual volume copy creation, and does not include all steps in the process.
29
Subsystem Performance
30
Performance 고려 사항 최대 쓰기 속도는 최적화된 상황에서 확보가능1
워크로드 특성에 따라 달라질 수 있음 블럭 사이즈와 Batch Window 프로세서와 채널 구성 고객 데이타의 압축가능성에 따라 달라질 수 있음 3:1 압축이 일반적 고객 데이타에 따라 압축률이 달라질 수 있음 최대 읽기 성능은 캐쉬에서 데이타 read시 가능 최대 쓰기 성능에 영향 미치는 요소에 동일하게 영향 받음 GRID 성능은 복제를 포함1 최대 읽기/쓰기 성능에 영향 미치는 요소에 동일하게 영향 동기 모드인 경우 영향 (Deferred / Immediate Copy) 네트워크 구성 / 가용 대역폭에 의하여 영향 It expected that the speaker is familiar with performance metrics. Data presented is from laboratory measurements using 800 MB volumes sizes, writing or reading 32KB blocks and using 20 buffers. The data pattern compresses at 2.67:1. Grid performance is presented in two ways 1) assuming that all host activity is on just one of the TS7700s and copies are done to the other and 2) host activities are on both TS7700s and copying is done in both directions. Data rates shown are the sum of both TS7700s in that case. 1Laboratory measurements, 800MB volumes, 32KB block size, 20 buffers
31
TS7700 Virtualization Engine FICON 성능
It is expected that the speaker is familiar with performance metrics. The bar chart shows our improvements over the last few years. A separate white paper and presentation of performance will be available after announcement.
32
TS7700 Virtualization Engine GRID 성능1
It is expected that the speaker is familiar with performance metrics. The bar chart shows our improvements over the last few years. A separate white paper and presentation of performance will be available after announcement. 1Local Area Network Connection, 0 distance, two cluster GRID
33
A short preview of what’s in STORE for you
Product Roadmap A short preview of what’s in STORE for you
34
TS7700 Design Objectives 최신 IBM 기술을 적용 가상화 테이프의 선도적 역할을 확장
성능 개선을 위한 IBM System p5+ 서버 캐쉬 용량의 혁신적 증가를 위한 IBM modular disk subsystem 가상화 테이프의 선도적 역할을 확장 소프트웨어 아키텍쳐를 재설계 기존 코드의 상당 부분을 재사용 성능 또는 기능을 획기적으로 개선시키기 위한 요소는 재개발 새로운 고객의 요구 지원 Information lifecycle를 비용 효율적으로 관리 비지니스 연속성을 위한 요구 지원 하드웨어 아키텍쳐 확장 고가용성 서브시스템 지원 planned 또는 unplanned outage로 인한 중단 최소화 고객의 투자 보호 기존 B10/B20 VTS의 업그레이드 경로 제공
35
TS7700 Statement of Direction
IBM 향후 계획 : 3952 Model F05 Tape Frame에 second TS7740 Server (Machine Type 3957, Model V06) 설치를 지원 TS7700 to the 3494 tape library에 TS7700 연결 지원 VTS Models B10/B20에서 TS7740 서버로의 업그레이드 교체 지원 TS1120 테이프 드라이브의 암호화 기능 활용 카트리지 “set” 상호 교환 및 스토리지로의 export 을 허용하기 위하여 Import/Export 기능 향상 Copy Export function은 재해 복구 용도로 standalone 또는 GRID TS7700에서 논리적 볼륨 export 지원 three site에서 full-duplex communication 지원 Delivered Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change without notice.
36
Potential Business Benefits
37
Why choose the IBM TS7700 Virtualization Engine?
1세대 VTS는 테이프 프로세싱을 완전히 변경 2세대와 3세대 VTS에서 성능과 용량 개선 PtP VTS는 비지니스 연속성 향상과 복구 시간을 절감 IBM는 테이프 기술에 지속적으로 투자합니다. 테이프 드라이브 기술에 있어 업계에서 리더로 자리매김 모든 영역의 테이프 드라이브, 라이브러리, 가상 테이프 서브 시스템을 제공 ROI를 최대화 하기 위한 소프트웨어와 서비스의 다양한 구성 제공 테이프 드라이브 암호 지원을 통해 데이타 보호 제공 TS7700는 추가적인 비용 절감을 제공합니다. 가상화는 적은 리소스에 낮은 비용으로 더 많은 데이타 지원 DFSMS 지원으로 자동화 스토리지 관리 지원 구성 및 환경적인 요구 사항을 간소화 고 성능 및 대용량 제공
38
GRID 컴퓨팅과 On Demand 기업 지원
가상화 엔진 TS7700 인프라 스트럭춰 최적화 지원 워크로드 관리 및 통합 원활화 정보 검색 시간 절감 데이타 접근 및 통합 향상 information 접근 용이화 Supports global distribution 지원 탄력적인 고가용성 인프라 스트럭춰 지원 비지니스 연속성 Recovery 및 Failover Virtualize Outside The Enterprise Virtualize The Enterprise Virtualization Virtualize Unlike Resources Virtualize Like Resources
39
Technology
40
Content The value of FICON Attachment
The value of new GRID interconnection method Ownership and Ownership Takeover Copy Export Advanced Function Tape Volume Cache Management Logical Volume Pooling 3592 Cartridge Selection Considerations TS1120 Encryption Support FICON Channel failure recovery Extended Distance Support
41
The Value of FICON Attachment
인프라 스트럭춰 요구 사항 절감 좀더 적은 채널 관리 좀더 적은 director port 구매 필요 좀더 적은 channel addresses 필요 성능 개선 더 높은 통합 대역폭과 full duplex 운영을 통해 배치 수행시간 절감 가능 더 높은 단일 대역폭을 제공함으로써 단일 작업 수행 시간 절감 가능 비지니스 연속성을 위한 원격 접속 지원
42
The Value of IBM FICON Attachment (continued)
43
The Value of New GRID Interconnect Method
FICON에서 I/P 기반 interconnection으로 변경 기본 TS7700 가상화 엔진에 peering 기능 통합 인프라 스트럭춰 요구 사항 절감 가상화 테이프 컨트롤러 제거 channel extension hardware 제거 관리 단순화 관리를 위한 요소 단순화 (no VTC, channel extension hardware) Standard와 GROD 구성을 위한 단일 관리 인터페이스 제공
44
Ownership과 Ownership Takeover Mode
GRID 구성의 Volume Ownership 각 논리적 볼륨은 한 TS7700 클러스터에 속함 모든 변경 사항은 owner에 의해 관리됨 TS7700 클러스터가 mount 작동을 하기 위해서는 반드시 볼륨에 대한 소유권을 가져야 함 볼륨 소유권은 mount 작동시 TS7700 클러스터간에 동적으로 이전됨. Ownership Takeover Mode 논리적 볼륨에 대한 소유권을 지니고 있는 TS7700 장애시, Automatic Ownership Takeover Manager는 가용 TS7700 클러스터로 소유권 이전 가능 Ownership Takeover Manager는 각 TS7700 클러스터의 TS3000 System Console (TSSC)를 이용하여 클러스터의 상태를 독립적으로 확인 가능 장애 발생시, ownership takeover 모드가 자동적으로 활성화 됨
45
Copy Export offsite 장애 복구를 위하여 데이타 전송이 가능한 export function 지원
TS7700에 원본 데이타는 유지하면서 선택적으로 데이타 복제본 익스포트 소스 TS7700이 export한 물리적 볼륨을 지속적으로 관리 사용자는 복구 절차 수행 소스 TS7700에서 익스포트한 모든 데이타 복제본을 이용하여 빈 TS7700을 복구 테스트와 실제 장애 복구를 위한 복구 옵션 Grid 구성에서의 운영 (R1.4) 특정 TS7700에서 수행 논리적 볼륨을 익스포트 하기 위해서는 반드시 복제되어 있어야 함 standalone TS7700에 복구 가능
46
Copy Export Production Site Recovery Site Dual copy of data
Production Host Recovery Host Source TS7700 Recovery TS7700 TVC Database TVC Database Pool 09 Pool 09 Pool 01 Dual copy of data Export second copy w/DB Load all exported volumes in library Restore DB from latest export volume Production Site Recovery Site
47
Tape Volume Cache Management
job processing 지연을 최소화 하기 위해 고안 cache hit 최대화 두가지 옵션 - Preference Group 1 또는 0 논리적 볼륨별 선택 가능 Storage Class construct control Preference Group 0 – 캐쉬에서 우선적으로 삭제 Preference Group 1 – 캐쉬에서 유지 Storage Class으로 정의 LM panel Tape Library Specialist 할당 옵션 SMS이 자동 할당 IART 속성에 따라 backward 호환성 제공 (Initial Access Response Time provided by SMS Storage Class Construct) LM panel를 통해 정적 할당 시스템 디폴트
48
Tape Volume Cache Management (continued)
생성된 볼륨 중 80%가 ACS 루틴에 따라 접근이 거의 없는 부분으로 파악 Standard Cache Management Advanced Function Cache Management Space available for frequently accessed volumes Space : LRU Algorithm Copy : Priority / Size Space available for infrequently accessed volumes PG0 PG1 Copy : FIFO order Copy : Second in FIFO order Space : Delete First
49
Volume Pooling 3592 테이프 카트리지의 논리적 볼륨을 pool로 그룹화 32 물리적 pool 지원 Pool 관리
Media type control / intermix common scratch pool에서 borrow / return 독자적인 threshold와 정책 이용 Pool 관리 물리적인 볼륨을 pool 간 이동 논리적인 볼륨을 pool 간 이동 TS7700에 연결된 standalone과 GRID 지원 Library Manager panel 혹은 TS7700 GUI에서 Storage Group으로 정의
50
3592 Cartridge Selection Considerations
3592 JJ cartridge (100GB capacity) 개개의 데이타에 대한 검색 응답 속도가 중요한 경우 migrate된 data set을 recall시 다수의 data set의 복구 시간이 중요한 경우 600GB 복구시 두개의 500GB 카트리지보다 6개의 100GB 카트리지에서 동시에 복구하는 것이 더 빠름 3592 JA cartridge (500GB capacity) 일반적으로 검색 응답 속도가 치명적이지 않은 경우 Full Volume Dump Tape transaction log (MI/MO) HSM ABARS HSM Recycle target 3592 JB cartridge (700GB capacity) 대용량 데이타 요구시 TS1120 테이프 드라이브를 native E05 mode 운영해야 함 JA과 JB 카트리지 호환 구성 common scratch pool로 특정 풀에 할당하거나 추가 가능 borrow/return 가능 transparent backup copy를 만들기 위한 향상된 정책 관리 사용 미디어 에라시 자동 복구 가능
51
TS1120 암호 지원 요구 사항: 32 physical pool중 하나이상에서 암호화 활성화 가능
TS1120 테이프 드라이브는 native format 모드로 활성화 되어야 함 FC 9900는 반드시 필요 32 physical pool중 하나이상에서 암호화 활성화 가능 TS7700 이더넷 네트워크를 통한 key 관리 인터페이스 제공 암호화 키 요청은 primary key manager의 IP address로 전송되고, TS7700을 통해 드라이브로 전달됨 encryption enabled pool의 물리적인 볼륨에서 논리적인 볼륨을 읽기 위해서, TS7700은 key management interface를 이용하여 데이타를 복호화함
52
Extended Distance Support
TS7700 CPU FICON (used for host attachment) up to 100 km DWDM TS7700 CPU Director FICON with DWDM (used for host attachment) up to 250 km TCP/IP Switch >250 km with Channel Extender TS7700 TS7700 Opt’l Channel Extender CPU TCP/IP (used for volume replication) dependant on network connectivity
53
VTS Migration
54
Content VTS Migrations Supported Migrations Migration Process
Data Format Conversion
55
지원 가능 마이그레이션 내역 B10 또는 B20 VTS/TS3500 tape library (3584) 에서 TS7700/TS3500 tape library B10 또는 B20 VTS/3494 tape library (3584) 에서 TS7700/3494 tape library 각 VTS가 서로 다른 TS3500 테이프 라이브러에서 연결되어 있는 PtP VTS에서 두개의 GRID와 TS3500과 연결되는 TS7700 각 VTS가 서로 다른 3494 테이프 라이브러에서 연결되어 있는 PtP VTS에서 두개의 GRID와 3494와 연결되는 TS7700 각 VTS가 동일 TS3500 테이프 라이브러에서 연결되어 있는 두개의 표준 VTS에서 동일 TS3500에 연결된 단일 TS7700 3494 테이프 라이브러리에 연결된 VTS에서 TS3500 테이프 라이브러리에 연결된 TS7700 각 VTS가 서로 다른 3494 테이프 라이브러에서 연결되어 있는 PtP VTS에서 두개의 GRID와 TS3500 테이프 라이브러리와 연결되는 TS7700 각 VTS가 서로 다른 3494 테이프 라이브러에서 연결되어 있는 두개의 표준 VTS에서 동일 TS3500에 연결된 단일 TS7700 TS3500 테이프 라이브러리에 연결된 VTS에서 서로 다른 TS3500 테이프 라이브러리 각 VTS가 서로 다른 TS3500 테이프 라이브러에서 연결되어 있는 두개의 표준 VTS에서 TS3500 테이프 라이브러리에 연결되어 있는 단일 TS7700 (TS7700와 연결된 TS3500 테이프 라이브러리는 기존 VTS와 연결된 TS3500 테이프 라이브러리와 동일 가능)
56
마이그레이션 고려 사항 마이그레이션시 백엔드 테이프 드라이브로는 3592 J1A 또는 TS1120을 사용해야 하며, 모든 VTS 데이타는 3592 미디어에 있어야 함. VTS가 백엔드 테이프 드라이브를 연결시 2-Gbps 또는 4-Gbps를 모두 지원하지만, TS7700은 4-Gbps 스위치만을 지원
57
Data Format Conversion
Completely transparent to customer and applications B10/B20 format의 논리적 볼륨들을 읽어들여, TS7700 exportable format으로 기록됨 사용자는 변환 속도 조절 가능: 특정 논리적 볼륨 recalling reclamation의 사용량 또는 사용기간 설정 추후에 export하기 위해서는, pool내의 모든 논리적 볼륨이 TS7700 format이어야 함
58
Replace B10/B20 with a TS7700 (Box Swap)
Preserves the library, 3952 drives and media 호스트에서 B10/B20를 offline으로 변경 B10/B20’s ADSM 데이타 베이스 축출 Host, Library Manager 및 Drive에서 B10/B20 절체 TS7700를 Host, Library Manager 및 Drives, teach library에 연결 ADSM data를 TS7700의 DB2 database에 임포트 변경된 library definition 및 IODF 활성화 호스트에서 TS7700 online으로 변경
59
Thank You
Similar presentations