Download presentation
Presentation is loading. Please wait.
Published byAlberta Bruce Modified 6년 전
1
Chapter 24. Coulometry 1) Electrogravimetry: sample soln.+ Pt전극(wire, gauze) 직류전압 加 ┏ 일정전압법 (Constant applied cell potential) ┃ 일정전류법 (Constant electrolysis current) ┗일정작업전극전위 (Constant working electrode potential) 정량성분 , 전해석출 weighing (금속의 순도, 합금성분의 정량에 利用) 2) Coulometry: sample soln. + 일정 전위의 전압 加 (전류효율100%) 소요된 전기량 측정
2
Electrogravimetry 일정전위분해법 : 황산구리 용액에 Pt wire 및 Pt gauze (150cm2)전극을 0.0220M Cu ml M H+ 용액에 담궈 (cell of 0.50 Ω) 직류전압 加 전기분해 Cathode : Cu2++2e- Cu 석출 Eo = 0.34 V Anode : 1/2O2+2H++2e- = H2O Eo = 1.23 V 석출 전 후의 전극무게 측정 정량 Deposit 의 physical characteristic에 영향을 주는 요소: ① Current density ② Temp. ③ Complexing agent 의 존재 실험적으로 결정 Electrolysis : Eapp=EC-Ea+Πc+Πa-IR (24-1)
3
24A-1 Current-Voltage relationships during an electrolysis.
▪ Initial Thermodynamic Potential of the cell Standard potential data for the two half-reactions in the cell under consideration are Using the method shown in Ex 22-6, the thermodynamic potential for this cell can be shown to be V in M Cu ml M H+ solution. When a potential of -2.5 V is applied to the cell, Iinit = 1.5 A. (See Fig.14-1a) ▪ Current changes during an electrolysis at constant applied potential; It = Ioe-kt , k = 25.8DA / Vδ Typically, D = 10-5 cm2/s, δ = 2 x 10-3 cm
4
1-2. Constant current electrolysis :
By maintaining the current : 전해 동안 주기적 전압증가 要. Fig. 24-2
5
Eapp = (Ea+ηa)-(Ec+ηc)+IR
Ec = EoCu2+,Cu /2log[Cu2+] ex) 0.01M Cu % 전해에 必要한 voltage EC = /2*log[10-2]=0.28 V 전해 종료시 EC = /2*log[10-5] = 0.19 V (저하) ηa ,ηc H+ 의 accumulation depolarizer 첨가 즉 Cu2++H2O = Cu+1/2O2(g)+H+ NO3-+10H++8e- = NH4++3H2O Electrode reaction 의 속도에 의존 (Pt에서 거의 무시) IR 강하 이론적인 加 전압 값보다 약간 더 큰 전압 加
6
1-3. Controlled potential electrolysis (limited cathode potential electrolysis)
장치: ( working elec.의 전위 reference에 대해 측정 이론 값 만큼 전위 加 ) Reference 전극에 대해 일정한 전위를 설정 저항 조정 working electrode의 전위가 일정하게 조절
7
적용 : 두 종류의 금속 수소보다 양성 , 전극전위 비슷
분리 곤란(일정전류법) Controlled potential electrolysis 사용 전류 I 시간 t 에 대해 지수 함수적으로 감소 I = Ie-kt . logI = kt+logI0 Ct/C0 = it/io = e-(DA/Vδ)t = (DA/vg)t v : 용액의 volume δ : 확산 층의 두께 Ct/C0 = e-ktk =mA/V m : mass transfer coefficient = D/δ k = 25.8DA/(Vδ)
8
1-4. Mercury cathode electrolysis
음극: 백금대신 수은->전해 Mn++ne+Hg M(Hg) 원소의 분리에 利用 ex) [Ag+] = 10-6M, [Cu2+] = 0.1M 일 때 EC = 0.08+(-0.35) =0.45V EC-ηC = = 0.38(V) 구리 EC =0.31V이므로 0.38V volt 에서 Ag+을 정량적 석출 可能 1-5. Internal electrolysis 양극 : 석출금속보다 음의 단위를 가진 금속 음극: 백금 두 극 사이에 격막을 놓으면 전지 형성내부전해법
9
24B An Introduction to coulometric methods of analysis
Coulometry Analyte를 정량적으로 다른 산화상태로 변화시키는데 필요로 하는 전기량 2. Controlled-potential coulometry idt = Q = nFw/M F ; ±1.6(≒96500)C/g당량 Q를 측정 w계산 w : 산화 환원 물질의 무게 , M : formula weight, Q : coulombs의 수
10
24B-1 Units for Quantity of Electricity
The quantity of electricity or charge or charge is measured in units of coulombs(c). 24B-2 Type of Coulometric Methods ┏ Constant potential coulometry ┗ Constant current coulometry
12
2-1. Constant potential coulometry
Q = Idt = I0e-kt dt = I0(1+10-kt)/2.3033k ≒ I0/2.303k I = I0e-kt, logI = kt +log I0 식에서 I0와 kt를 구하여 Q값 계산 2-2. Constant current coulometry, (전기량 적정) I = constant이므로 Q = It에서 t측정하여 Q계산 정량물질의 선택적 전해가 어렵다. 전해에 의해 생긴 제2 물질 적정하여 정량
13
2-3. Coulometers 종류 H2, O2 coulometer Ag coulometer H2, N2 coulometer Cu coulometer H2 coulometer 적산 coulometer 1. H2-O2 coulometer 뷰렛모양의 전해용기에 K2SO4 용액을 담고 Pt를 전극으로 하여 전기분해 발생 전 H2-O2 의 부피 측정 (16.80ml/1mg)
14
2. Ag coulometer Cathode : Pt crueible containing AgNO3 solon Anode : Ag 전극 Pt+석출 전 Ag 무게 측정 Q계산 3. N2-H2 coulometer Hydrazine sulfate 전기분해 수소, 질소 발생 gas 양 측정 전기량 계산 4. 적정 전기량계 양극 : 은 KBr+K2SO4용액 전해 음극 : Pt 2Ag+2Br-+2H2O 2AgBr+H2+2OH- OH-을 0.01 NHCl로 적정하여 구한다.
15
24C Controlled-potential coulometry
24C-1 Instrumentation ▪ Cells Fig 24-5 illustrates two types of cells that are used for potentiostatic coulometry. ▪ Potentiostats A potentiostat is an electronic device that maintains the potential of a working electrode at a constant level relative to a reference electrode. Fig 24-6 is a schematic of an apparatus for controlled=potential coulometry, which contains a somewhat different type of potentiostat. ▪ Integrators As shown in Section 3E-3, analog integrators can be constructed from operational amplifier circuits.
16
Cl3CCOO- + H+ + 2e- Cl2HCCOO- + Cl2
24C-2 Applications Controlled-potential coulometric methods have been applied to more than fifty elements in inorganic compounds. Cl3CCOO- + H+ + 2e- Cl2HCCOO- + Cl2
17
24D Coulometric titration
24D-1 Electrical Apparatus Fig 24-7 is a conceptual diagram of a coulometric titration apparatus showing its main components. Fig 24-8 is a photo of one of a number of automated coulometric titrators on the market. The instrument in Fig 24-8 is specifically designed for the Karl Fischer determination of water. ▪ Cells for coulometric Titrations A typical coulometric titration cell is shown in Fig 24-9. Note that the apparatus shown in Fig provides either hydrogen or hydroxide ions depending on which arm is used.
18
24D-2 Applications of Coulometric Titrations
▪ Neutralization Titrations Both weak and strong acids can be titrated with a high degree of accuracy using hydroxide ions generated at a cathode by the reaction. ▪ Precipitation and Complex-Formation Titrations A variety of coulometric titrations involving anodically generated silver ions have been developed(see Table 24-1).
19
▪ Coulometric Titration of Chloride in Biological Fluids
The accepted reference method for determining chloride in blood serum, plasma, urine, sweat, and other body fluids is the coulometric titration procedure. (ncl-)u = t u /t s X (ncl-)s
20
▪ Oxidation-Reduction Titrations
Table 24-2 indicates the variety of reagents that can be generated coulometrically and the analyses to which they then have been applied.
21
① Variation in the current source of error
▪ Comparison of Coulometric and Volumetric Titrations There are several interesting analogies between coulometric and volumetric titration methods. Titration error ① Variation in the current source of error ② Departure of the process from 100% current efficiency ③ Error in the measurement of current ④ Error in the measurement of time ⑤ Titration error due to the difference between the equivalence point & end point 정밀 : 0.01%
22
실험 및 이론: 1) Pt gauze를 nitric acid rinsed-dried weighing 2) Deposition : Eapp=(Ea+ηa)-(EC+ηC)+iR EC=E°cu /2log[Cu2+] @ 0.01M-Cu % 전해에 필요한 Voltage EC= /2log[10-2]=0.28V ηa : electrode reaction의 속도에 의존 Pt에서는 거의 무시 ηe : H+의 accumulation (depolarizer) (stirring) Cu2++H2O <-> Cu+1/2O2(g)=2H+ 특정 이온만의 분리 다양한 기술 필요
23
* IR 강하로 인해 이론적인 加 전압 값보다 약간 더 큰 전압은 加해야 한다.
H+의 방해감소 (depolarizer첨가) H2 gas발생(spongy식의 전착) (Cu2+의 경우) Cathode : Cu2++2e-=Cu Anode : 1/2O2+2H+=2e- <-> H2O NO3-+10H+=8e- <-> NH4++3H2O Cu H2발생 無
24
3-1. Electrolysis at controlled potential
Copper, ion 혼합물 정량 시 Working elec.의 전위 reference에 대해 측정 이론값 만큼 加 보정해 주며 전압 加 3-2. Electrolytic separations Easily reduced metals from small currents of less easily reduced material
25
3-3. Controlled-potential coulometry
Analyte chemical state의 chrage q를 측정 phy. constant에 따라 양을 계산 w=QM/nF w : 산화, 환원전 물질의 무게 F : ±1.6coulomb/g M : 물질의 분자량 Q : cell을 지나는 전하의 수 q=it
Similar presentations